dc.description.abstractIn the present study, a solid phase extraction procedure has been presented for the separation and preconcentration of aluminium (Al) and lead (Pb) in various matrixes such as water, cola and fruit juice samples. 4-[(3-amino-5-{[(2-hydroxyphenyl) methylidene] amino}-1H-pyrazol-4-yl) diazenyl] benzoic acid (AHPMAPDAB) was used as a ligand. AHPMAPDAB chelates of Al and Pb ions in aqueous solutions were adsorbed on polystyrene-graft-ethyl methacrylate copolymer (Poly S-15-g-EMA(120)). Various experimental and analytical parameters such as sample solution pH, sample volume, flow rate of sample solution and eluent, volume and concentration of eluent, amount of ligand and adsorbent, effect of common matrix ions and capacity of adsorbent were investigated. The adsorbed metal ions on resin were eluted with 6mL of 2molL(-1) HCl solutions and their concentrations were determined by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Under the optimised conditions, limits of detections were 0.32 mu gL(-1) and 0.24 mu gL(-1) for Al and Pb, respectively. The accuracy of the procedure was confirmed by analysing certified materials (NIST SRM 1643e, Trace elements in water) and spiked real samples. The developed procedure was successfully applied to real samples.en_US
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [110T111]en_US
dc.description.sponsorshipWe would like to thank the Scientific and Technological Research Council of Turkey (TUBITAK grant no. 110T111). The authors are also grateful to Prof. Dr. Memet Sekerci for ligand synthesis.en_US
dc.language.isoengen_US
dc.publisherTAYLOR & FRANCIS LTDen_US
dc.relation.isversionof10.1080/03067319.2013.864646en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectpreconcentrationen_US
dc.subjectbeveragesen_US
dc.subjectleaden_US
dc.subjectaluminiumen_US
dc.subjectcontinuum source atomic absorption spectrometryen_US
dc.subjectgraft polymeren_US
dc.titleHigh-resolution continuum source flame atomic absorption spectrometric (HR-CS FAAS) determination of trace aluminium and lead in water and some beverage samples after separation and preconcentration procedureen_US
dc.typearticleen_US
dc.relation.journalINTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRYen_US
dc.contributor.departmentKırşehir Ahi Evran Üniversitesi, Fen-Edebiyat Fakültesi, Kimya Bölümüen_US
dc.identifier.volume94en_US
dc.identifier.issue6en_US
dc.identifier.startpage579en_US
dc.identifier.endpage593en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster