Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorCiftci, Harun
dc.contributor.authorEr, Cigdem
dc.date.accessioned2019-11-24T20:38:42Z
dc.date.available2019-11-24T20:38:42Z
dc.date.issued2013
dc.identifier.issn0167-6369
dc.identifier.urihttps://dx.doi.org/10.1007/s10661-012-2745-3
dc.identifier.urihttps://hdl.handle.net/20.500.12513/2564
dc.descriptionWOS: 000314033300056en_US
dc.descriptionPubMed ID: 22740156en_US
dc.description.abstractIn the present study, a separation/preconcentration procedure for determination of aluminum in water samples has been developed by using a new atomic absorption spectrometer concept with a high-intensity xenon short-arc lamp as continuum radiation source, a high-resolution double-echelle monochromator, and a charge-coupled device array detector. Sample solution pH, sample volume, flow rate of sample solution, volume, and concentration of eluent for solid-phase extraction of Al chelates with 4-[(dicyanomethyl)diazenyl] benzoic acid on polymeric resin (Duolite XAD-761) have been investigated. The adsorbed aluminum on resin was eluted with 5 mL of 2 mol L-1 HNO3 and its concentration was determined by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Under the optimal conditions, limit of detection obtained with HR-CS FAAS and Line Source FAAS (LS-FAAS) were 0.49 mu g L-1 and 3.91 mu g L-1, respectively. The accuracy of the procedure was confirmed by analyzing certified materials (NIST SRM 1643e, Trace elements in water) and spiked real samples. The developed procedure was successfully applied to water samples.en_US
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [110T111]en_US
dc.description.sponsorshipWe would like to thank the Scientific and Technological Research Council of Turkey (TUBITAK grant no. 110T111)en_US
dc.language.isoengen_US
dc.publisherSPRINGERen_US
dc.relation.isversionof10.1007/s10661-012-2745-3en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPreconcentrationen_US
dc.subjectTracemetalen_US
dc.subjectAluminumen_US
dc.subjectSeparationen_US
dc.titleSolid-phase extraction and separation procedure for trace aluminum in water samples and its determination by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS)en_US
dc.typearticleen_US
dc.relation.journalENVIRONMENTAL MONITORING AND ASSESSMENTen_US
dc.contributor.departmentKırşehir Ahi Evran Üniversitesi, Fen-Edebiyat Fakültesi, Kimya Bölümüen_US
dc.identifier.volume185en_US
dc.identifier.issue3en_US
dc.identifier.startpage2745en_US
dc.identifier.endpage2753en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster