dc.description.abstractElectrochemical properties and diffusion-adsorption behavior of risperidone (RPN), an anti-physcotic drug, on hanging mercury drop electrode (HMDE) were carried out in Britton-Robinson (BR) buffer. Some electrochemical parameters such as diffusion coefficient, number of transferred electrons and proton participated to its reduction mechanism and surface coverage coefficient were calculated from the results of cyclic voltammetry, square-wave voltammetry and constant potential electrolysis. RPN was found to be reduced with single two-electron/ two-proton quasi-reversible mechanism controlled mainly by adsorption with some diffusion contribution at the potential about -1.58 V (vs Ag|AgCl electrode). Experimental parameters were optimized to develop a new, accurate, rapid, selective and simple square-wave cathodic adsorptive stripping voltammetric (SWCAdSV) method for direct determination of RPN in pharmaceutical dosage forms, spiked human urine and human serum samples without time-consuming steps prior to drug assay. This method was based on the relation between the peak current and the concentration of RPN and it was recognized that peak current of reduction wave linearly changes with the concentration of RPN in the concentration range of 1.5-150 nM, when optimum preconcentration potential -0.65 V and optimum preconcentration time 60 s were applied. In this method, limit of detection (LOD) was found as 5.18 nM (2.12 ppb). The method was successfully applied to determine the RPN content of commercial pharmaceutical preparations, spiked human serum and spiked human urine. The method was found to be highly accurate and precise, having a relative standard deviation of less than 4.80% for all applications.en_US
dc.language.isoengen_US
dc.publisherINST ORGANIC CHEM AND BIOCHEMen_US
dc.relation.isversionof10.1135/cccc2010156en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCyclic voltammetryen_US
dc.subjectElectrochemistryen_US
dc.subjectRisperidoneen_US
dc.subjectDrug assayen_US
dc.subjectSquare-wave adsorptive stripping voltammetryen_US
dc.subjectElectrochemical behavioren_US
dc.titleSQUARE-WAVE CATHODIC ADSORPTIVE STRIPPING VOLTAMMETRY OF RISPERIDONEen_US
dc.typearticleen_US
dc.relation.journalCOLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONSen_US
dc.contributor.departmentKırşehir Ahi Evran Üniversitesi, Fen-Edebiyat Fakültesi, Kimya Bölümüen_US
dc.identifier.volume76en_US
dc.identifier.issue3en_US
dc.identifier.startpage159en_US
dc.identifier.endpage176en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US