dc.contributor.author | Tasdemir, Ibrahim Hudai | |
dc.contributor.author | Akay, Mehmet Abdulkadir | |
dc.contributor.author | Erk, Nevin | |
dc.contributor.author | Kilic, Esma | |
dc.date.accessioned | 2019-11-24T20:38:52Z | |
dc.date.available | 2019-11-24T20:38:52Z | |
dc.date.issued | 2010 | |
dc.identifier.issn | 1040-0397 | |
dc.identifier.uri | https://dx.doi.org/10.1002/elan.201000100 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12513/2590 | |
dc.description | International Conference on Modern Electroanalytical Methods -- DEC 09-13, 2009 -- Sci Charles Univ Prague, Czech Chem Soc, Inst Phys Chem Acad Sci Czech Rep, Prague, CZECH REPUBLIC | en_US |
dc.description | WOS: 000281904400025 | en_US |
dc.description.abstract | Electrochemical behavior of Telmisartan and optimum conditions for its assay were investigated by using cyclic voltammetry and square-wave voltammetry. All studies were based on the quasi-reversible and adsorption-controlled electrochemical reduction signal of TS at about -1.50 V versus Ag/AgCl at pH 10.0 in Britton-Robinson buffer. The peak current was found to change linearly with concentration from 1.69 nM (0.87 mu g/L) to 27.5 nM (14.15 mu g/L). The limit of detection and the limit of quantification were found to be 1.05 nM (0.54 mu g/L) and 3.49 nM (1.79 mu g/L), respectively. The method was successfully applied to different samples with good recoveries at about 100%. | en_US |
dc.description.sponsorship | European Soc Electroanalytical Chem, Int Soc Electrochem | en_US |
dc.language.iso | eng | en_US |
dc.publisher | WILEY-V C H VERLAG GMBH | en_US |
dc.relation.isversionof | 10.1002/elan.201000100 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Telmisartan | en_US |
dc.subject | Square-wave cathodic adsorptive stripping voltammetry | en_US |
dc.subject | Pharmaceuticals | en_US |
dc.subject | Spiked human serum | en_US |
dc.subject | Hanging mercury drop electrode | en_US |
dc.title | Voltammetric Behavior of Telmisartan and Cathodic Adsorptive Stripping Voltammetric Method for Its Assay in Pharmaceutical Dosage Forms and Biological Fluids | en_US |
dc.type | article | en_US |
dc.relation.journal | ELECTROANALYSIS | en_US |
dc.contributor.department | Kırşehir Ahi Evran Üniversitesi, Fen-Edebiyat Fakültesi, Kimya Bölümü | en_US |
dc.identifier.volume | 22 | en_US |
dc.identifier.issue | 17-18 | en_US |
dc.identifier.startpage | 2101 | en_US |
dc.identifier.endpage | 2109 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |