dc.description.abstractObjective: To compare the performance times and success rates of the classic Macintosh laryngoscope (CML) or video laryngoscope (VL) with endotracheal intubation (ETI) and second-generation supraglottic airway devices (SAD) in difficult airway management during cardiopulmonary resuscitation (CPR). Materials and methods: Classic Macintosh Laryngoscope (D1), C-Mac (R) videolaryngoscope (D2), Laryngeal Tube LTS-D (R) (D3), LMA Supreme (R) (D4), i-gel (R) (D5) and air-Q (R) (D6) were used to achieve a secure airway in the study. In the first week, 60 trainee paramedics made ten attempts with each device using a manikin that was immobilized with a collar. Eight weeks later, the trainees made ten more attempts with each device. Application times, success rates, and the device preferences of the trainees were compared. Results: When we analyzed total application times, the shortest times were identified in the D5 and D6 groups. The success rate was low in the D1 group in the first ten attempts. There was no statistically significant difference in the last ten attempts. When we evaluated application skills after eight weeks, application times were improved significantly in all groups. The trainees stated that they would prefer D2, D5, and D3 devices during CPR. Conclusions: Practitioners with sufficient experience had high success rates with both ETI and SAD even though application times were different during CPR. SADs without a cuff seem advantageous compared with the others regarding total application times. However, no success rate difference was observed with the other devices.en_US
dc.language.isoengen_US
dc.publisherE-CENTURY PUBLISHING CORPen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectVideolaryngoscopeen_US
dc.subjectlaryngeal tubeen_US
dc.subjectLMA supremeen_US
dc.subjecti-gelen_US
dc.subjectair-Qen_US
dc.subjectendotracheal intubationen_US
dc.titleComparison of endotracheal intubation and a new-generation supraglottic airway device in training of difficult airway: a manikin studyen_US
dc.typearticleen_US
dc.relation.journalINTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINEen_US
dc.contributor.departmentKırşehir Ahi Evran Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri, Anesteziyoloji ve Reanimasyon ABDen_US
dc.identifier.volume11en_US
dc.identifier.issue6en_US
dc.identifier.startpage5921en_US
dc.identifier.endpage5928en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster