Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDagli, Recai
dc.contributor.authorBayir, Hakan
dc.contributor.authorDadali, Yeliz
dc.contributor.authorTokmak, Turgut Tursem
dc.contributor.authorErbesler, Zeynel Abidin
dc.date.accessioned2019-11-24T21:00:44Z
dc.date.available2019-11-24T21:00:44Z
dc.date.issued2017
dc.identifier.issn2149-0937
dc.identifier.issn2149-276X
dc.identifier.urihttps://dx.doi.org/10.5152/TJAR.2017.80269
dc.identifier.urihttps://hdl.handle.net/20.500.12513/3446
dc.descriptionWOS: 000399412700011en_US
dc.descriptionPubMed ID: 28439443en_US
dc.description.abstractObjective: In this study, we aimed to determine the success rate of nasoenteric tube (NET) insertion into the postpyloric area using ultrasonography (USG) and compare with the commonly used method direct abdominal graphy. Methods: A single anaesthesiologist placed all the NETs. The NET was visualised by two radiologists simultaneously using USG. The localisation of the tube was confirmed using an abdominal graph in all patients. Results: The blind bedside method was used for NET insertion into 34 patients. Eleven of the tubes were detected passing through the postpyloric area using USG. In one case, the NET could not be visualised in the postpyloric area using USG; however, it was detected in the postpyloric area through control abdominal radiography. In 22 patients, NETs were detected in the stomach using control abdominal radiography. The rate of imaging post pyloric using USG was 91.6%. When all cases were considered, catheter localisation was detected accurately using USG by 97% (33 in 34 patients). Conclusion: USG is a reliable and practical alternative to radiography, which can be used to detect localisation of the nasogastric tube and NET.en_US
dc.language.isoengen_US
dc.publisherAVESen_US
dc.relation.isversionof10.5152/TJAR.2017.80269en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectNasoenteric tubeen_US
dc.subjectultrasonographyen_US
dc.subjectradiographyen_US
dc.subjectenteral feedingen_US
dc.subjectaspirationen_US
dc.titleRole of Ultrasonography in Detecting the Localisation of the Nasoenteric Tubeen_US
dc.typearticleen_US
dc.relation.journalTURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATIONen_US
dc.contributor.departmentKırşehir Ahi Evran Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri, Anesteziyoloji ve Reanimasyon ABDen_US
dc.identifier.volume45en_US
dc.identifier.issue2en_US
dc.identifier.startpage103en_US
dc.identifier.endpage107en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster