Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorCanturk, Mehmet
dc.contributor.authorCanturk, Fusun Karbancioglu
dc.contributor.authorDagli, Recai
dc.contributor.authorDagli, Selda Songur
dc.date.accessioned2019-11-24T21:00:44Z
dc.date.available2019-11-24T21:00:44Z
dc.date.issued2016
dc.identifier.issn1940-5901
dc.identifier.urihttps://hdl.handle.net/20.500.12513/3447
dc.descriptionWOS: 000391260800118en_US
dc.description.abstractObjective: This study aims to determine the effect of age, height, weight, BMI, hip/shoulder width ratio, and vertebral column length on the spread of spinal anesthesia in term parturient. In pregnant patients with a larger hip width and a relative narrow shoulder width, more cephalad spread of spinal anesthesia is observed with a fixed dose of hyperbaric bupivacaine. We hypothesized that the increase in cephalad spread of spinal anesthesia may be correlated with the increased hip/shoulder width ratio. Methods: Age, weight, height, body mass index, hip width, shoulder width, hip/shoulder width ratio, and vertebral column length were recorded for 75 term parturient. The L4-L5 interspace was introduced and 2 ml 0.5% hyperbaric bupivacaine was injected subarachnoid in 10 seconds without barbotage. Pearson and Sperman's Rho Correlation Tests were used for the analysis of correlation between patient characteristics and the cephalad spread of spinal anesthesia. Results: Hip/shoulder width ratio had a positive correlation with the cephalad spread of spinal anesthesia (P=0.037). Other patient variables in the present study did not have correlation with the cephalad spread of spinal anesthesia (P>0.05). Vertebral column length had correlation with patient height (P=0.01). Conclusions: The cephalad spread of spinal anesthesia is correlated with hip/shoulder width ratio in term parturient patients. Vertebral column length has no correlation with the spinal anesthesia spread but correlates with the height of the parturient. The hip/ shoulder width ratio may be more important than either patient height or vertebral column length in predicting the cephalad spread of spinal anesthesia for each parturient.en_US
dc.language.isoengen_US
dc.publisherE-CENTURY PUBLISHING CORPen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAnesthesiaen_US
dc.subjectspinalen_US
dc.subjecthipen_US
dc.subjectobstetricen_US
dc.subjectpregnancyen_US
dc.titleThe spread of spinal anesthesia in term parturient: effect of hip/shoulder width ratio and vertebral column lengthen_US
dc.typearticleen_US
dc.relation.journalINTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINEen_US
dc.contributor.departmentKırşehir Ahi Evran Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri, Anesteziyoloji ve Reanimasyon ABDen_US
dc.identifier.volume9en_US
dc.identifier.issue11en_US
dc.identifier.startpage21562en_US
dc.identifier.endpage21567en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster