dc.descriptionPubMed ID: 30581326en_US
dc.description.abstractBackground: The Six-Sigma Methodology is a quality measurement method in order to evaluate the performance of the laboratory. In the present study, it is aimed to evaluate the analytical performance of our laboratory by using the internal quality control data of immunoassay tests and by calculating process sigma values. Methods: Biological variation database (BVD) are used for Total Allowable Error (TEa). Sigma values were determined from coefficient of variation (CV) and bias resulting from Internal Quality Control (IQC) results for 3 subsequent months. If the sigma values are >= 6, between 3 and 6, and < 3, they are classified as "world-class", "good" or "un acceptable", respectively. Results: A sigma value >6 was found for TPSA and TSH for the both levels of IQC for 3 months. When the sigma values were analyzed by calculating the mean of 3 months, folate, LH, PRL, TPSA, TSH and vitamin B12 were found > 6. The mean sigma values of CA125, CA15-3, CA19-9, CEA, cortisol, ferritin, FSH, FT3, PTH and testosteron were > 3 for 3-months. However, AFP, CA125 and FT4 produced sigma values < 3 for varied months. Conclusions: When the analytical performance was evaluated according to Six-Sigma levels, it was generally found as good. It is possible to determine the test with high error probability by evaluating the fine sigma levels and the tests that must be quarded by a stringent quality control regime. In clinical chemistry laboratories, an appropriate quality control scheduling should be done for each test by using Six-Sigma Methodology.en_US
dc.language.isoengen_US
dc.publisherDE GRUYTER OPEN LTDen_US
dc.relation.isversionof10.1515/jomb-2017-0026en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectcoefficient of varianceen_US
dc.subjectbiasen_US
dc.subjectsix sigmaen_US
dc.subjecttotal allowable erroren_US
dc.subjectimmunassay testsen_US
dc.titleTHE EVALUATION OF ANALYTICAL PERFORMANCE OF IMMUNOASSAY TESTS BY USING SIX-SIGMA METHODen_US
dc.typearticleen_US
dc.relation.journalJOURNAL OF MEDICAL BIOCHEMISTRYen_US
dc.contributor.departmentKırşehir Ahi Evran Üniversitesi, Tıp Fakültesi, Temel Tıp Bilimleri, Tıbbi Biyokimya ABDen_US
dc.identifier.volume36en_US
dc.identifier.issue4en_US
dc.identifier.startpage301en_US
dc.identifier.endpage308en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster