Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorAcer, Niyazi
dc.contributor.authorKamasak, Burcu
dc.contributor.authorKarapinar, Burak Oguzhan
dc.contributor.authorYetkin, Esra Akkus
dc.contributor.authorİpekten, Funda
dc.contributor.authorGray, Serap Bastepe
dc.contributor.authorDegirmencioglu, Levent
dc.contributor.authorIlıca, Ahmet Turan
dc.date.accessioned2022-04-15T08:48:44Z
dc.date.available2022-04-15T08:48:44Z
dc.date.issued2022en_US
dc.identifier.citationAcer N, Kamaşak B, Karapınar BO, Akkuş Yetkin E, İpekten F, Baştepe Gray S, et al. A Comparison of Automated Segmentation and Manual Tracing of Magnetic Resonance Imaging to Quantify Lateral Ventricle Volumes. Erciyes Med J 2022; 44(2): 148–55.en_US
dc.identifier.issn2149-2247
dc.identifier.issn2149-2549
dc.identifier.urihttps://doi.org/10.14744/etd.2021.73920
dc.identifier.urihttps://hdl.handle.net/20.500.12513/4373
dc.description.abstractObjective: Ventricular volume measurements have been proposed as a useful biomarker for several neurological diseases. The goal of this study was to compare the performance of 3 fully-automated tools, volBrain (http://volbrain.upv.es ), ALVIN (Automatic Lateral Ventricle Delineation) (https://sites.google.com/site/mrilateralventricle/), and MRICIoud (http://mricloud.org ), with expert hand tracing to quantify lateral ventricle (LV) volume using magnetic resonance images. Materials and Methods: The sample comprised 24 healthy subjects (age: 25.1 +/- 5.7 years, all male). Volumes derived from each automated measurement were compared to hand tracing results performed by 2 specialists to assess the percent volume difference using the intraclass correlation coefficient (ICC), concordance correlation coefficient (CCC), Dice index value, and Bland-Altman analysis. Results: The ICC agreement of the Manual_1 and Manual_2 was very good (0.979), and there was no statistically significant difference (p>0.001). The volume difference of all methods was similar. The CCC with MRICloud and ALVIN was higher than that of volBrain. Bland-Altman plots indicated that the 3 automated methods demonstrated acceptable agreement. Conclusion: Compared with hand tracing, the LV volumes generated by MRICloud were more accurate than those of volBrain and ALVIN. LV volume values can provide valuable data related to the volumetric dependencies of the anatomical structures in various clinical conditions that can now be easily obtained using automated tools.en_US
dc.language.isoengen_US
dc.relation.isversionof10.14744/etd.2021.73920en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAlvinen_US
dc.subjectLateral ventricleen_US
dc.subjectManual tracingen_US
dc.subjectMRIClouden_US
dc.subjectBrainen_US
dc.titleA Comparison of Automated Segmentation and Manual Tracing of Magnetic Resonance Imaging to Quantify Lateral Ventricle Volumesen_US
dc.typearticleen_US
dc.relation.journalErcıyes Medıcal Journalen_US
dc.contributor.departmentTıp Fakültesien_US
dc.contributor.authorIDBurcu Kamaşak / 0000-0001-5340-1260en_US
dc.identifier.volume44en_US
dc.identifier.issue2en_US
dc.identifier.startpage148en_US
dc.identifier.endpage155en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster