dc.contributor.author | Özsoy, İsmail | |
dc.contributor.author | Kodak, Muhammed İhsan | |
dc.contributor.author | Karartı, Caner | |
dc.contributor.author | Özsoy, Gülşah | |
dc.contributor.author | Ertürk, Arzu | |
dc.contributor.author | Kahraman, Turhan | |
dc.date.accessioned | 2022-04-18T11:17:13Z | |
dc.date.available | 2022-04-18T11:17:13Z | |
dc.date.issued | 2022 | en_US |
dc.identifier.citation | Ozsoy, I., Kodak, M. I., Kararti, C., Ozsoy, G., Erturk, A., & Kahraman, T. (2022). Intra-and Inter-Rater Reproducibility of the Face-to-Face and Tele-Assessment of Timed-up and Go and 5-Times Sit-to-Stand Tests in Patients with Chronic Obstructive Pulmonary Disease. COPD: Journal of Chronic Obstructive Pulmonary Disease, 19(1), 125-132. | en_US |
dc.identifier.issn | 15412563 | |
dc.identifier.uri | https://doi.org/10.1080/15412555.2022.2038119 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12513/4381 | |
dc.description.abstract | Timed-Up and Go (TUG) and 5-Times Sit-to-Stand (5STS) are frequently used in clinical practice for patients with chronic obstructive pulmonary disease (COPD). The aim of the study was to investigate the intra- and inter-rater reproducibility of the TUG and 5STS as both face-to-face and tele-assessment tests in patients with COPD. Forty-four patients with diagnosed COPD were included. Evaluations were carried out face-to-face and tele-assessment (synchronized and asynchronized). Inter-reliability between face-to-face and tele-assessment was excellent for TUG (ICC = 0.977) and 5STS (ICC = 0.970). Inter-reliability between two tele-raters was also excellent for TUG (ICC = 0.995) with the SEM = 0.04, SEM95% = 0.08, and SDC95% = 0.10 s, and 5STS (ICC = 0.990) with the SEM = 0.06, SEM95% = 0.12, and SDC95% = 0.18 s. Intra-rater reliability of the tele-assessment (synchronized) was excellent for TUG (ICC = 0.976) and 5STS (ICC = 0.964). The SEM, SEM95%, and SDC95% values were computed as 0.08, 0.16, and 0.22 s for TUG, and 0.11, 0.22, and 0.31 s for 5STS, respectively. The TUG and 5STS tests are reproducible tele-assessment measures in patients with COPD with excellent intra- and inter-rater reproducibility. The authors recommend these tests as practical assessment tools in patients with COPD at home for tele-health interventions. The reported SEM, SEM95%, and SDC95% values can be used as a minimum change that needs to be observed to be confident that the observed change is real and not, potentially, a product of measurement error. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | NLM (Medline) | en_US |
dc.relation.isversionof | 10.1080/15412555.2022.2038119 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | 5-times sit-to-stand test | en_US |
dc.subject | chronic obstructive pulmonary disease | en_US |
dc.subject | reliability; | en_US |
dc.subject | Tele-assessment | en_US |
dc.subject | Timed-up and go test | en_US |
dc.title | Intra- and Inter-Rater Reproducibility of the Face-to-Face and Tele-Assessment of Timed-up and Go and 5-Times Sit-to-Stand Tests in Patients with Chronic Obstructive Pulmonary Disease | en_US |
dc.type | article | en_US |
dc.relation.journal | COPD: Journal of Chronic Obstructive Pulmonary Disease | en_US |
dc.contributor.department | Tıp Fakültesi | en_US |
dc.contributor.authorID | Arzu Ertürk / 0000-0002-8139-6750 | en_US |
dc.identifier.volume | 19 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 125 | en_US |
dc.identifier.endpage | 132 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |