Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorÖzsoy, İsmail
dc.contributor.authorKodak, Muhammed İhsan
dc.contributor.authorKarartı, Caner
dc.contributor.authorÖzsoy, Gülşah
dc.contributor.authorErtürk, Arzu
dc.contributor.authorKahraman, Turhan
dc.date.accessioned2022-04-18T11:17:13Z
dc.date.available2022-04-18T11:17:13Z
dc.date.issued2022en_US
dc.identifier.citationOzsoy, I., Kodak, M. I., Kararti, C., Ozsoy, G., Erturk, A., & Kahraman, T. (2022). Intra-and Inter-Rater Reproducibility of the Face-to-Face and Tele-Assessment of Timed-up and Go and 5-Times Sit-to-Stand Tests in Patients with Chronic Obstructive Pulmonary Disease. COPD: Journal of Chronic Obstructive Pulmonary Disease, 19(1), 125-132.en_US
dc.identifier.issn15412563
dc.identifier.urihttps://doi.org/10.1080/15412555.2022.2038119
dc.identifier.urihttps://hdl.handle.net/20.500.12513/4381
dc.description.abstractTimed-Up and Go (TUG) and 5-Times Sit-to-Stand (5STS) are frequently used in clinical practice for patients with chronic obstructive pulmonary disease (COPD). The aim of the study was to investigate the intra- and inter-rater reproducibility of the TUG and 5STS as both face-to-face and tele-assessment tests in patients with COPD. Forty-four patients with diagnosed COPD were included. Evaluations were carried out face-to-face and tele-assessment (synchronized and asynchronized). Inter-reliability between face-to-face and tele-assessment was excellent for TUG (ICC = 0.977) and 5STS (ICC = 0.970). Inter-reliability between two tele-raters was also excellent for TUG (ICC = 0.995) with the SEM = 0.04, SEM95% = 0.08, and SDC95% = 0.10 s, and 5STS (ICC = 0.990) with the SEM = 0.06, SEM95% = 0.12, and SDC95% = 0.18 s. Intra-rater reliability of the tele-assessment (synchronized) was excellent for TUG (ICC = 0.976) and 5STS (ICC = 0.964). The SEM, SEM95%, and SDC95% values were computed as 0.08, 0.16, and 0.22 s for TUG, and 0.11, 0.22, and 0.31 s for 5STS, respectively. The TUG and 5STS tests are reproducible tele-assessment measures in patients with COPD with excellent intra- and inter-rater reproducibility. The authors recommend these tests as practical assessment tools in patients with COPD at home for tele-health interventions. The reported SEM, SEM95%, and SDC95% values can be used as a minimum change that needs to be observed to be confident that the observed change is real and not, potentially, a product of measurement error.en_US
dc.language.isoengen_US
dc.publisherNLM (Medline)en_US
dc.relation.isversionof10.1080/15412555.2022.2038119en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject5-times sit-to-stand testen_US
dc.subjectchronic obstructive pulmonary diseaseen_US
dc.subjectreliability;en_US
dc.subjectTele-assessmenten_US
dc.subjectTimed-up and go testen_US
dc.titleIntra- and Inter-Rater Reproducibility of the Face-to-Face and Tele-Assessment of Timed-up and Go and 5-Times Sit-to-Stand Tests in Patients with Chronic Obstructive Pulmonary Diseaseen_US
dc.typearticleen_US
dc.relation.journalCOPD: Journal of Chronic Obstructive Pulmonary Diseaseen_US
dc.contributor.departmentTıp Fakültesien_US
dc.contributor.authorIDArzu Ertürk / 0000-0002-8139-6750en_US
dc.identifier.volume19en_US
dc.identifier.issue1en_US
dc.identifier.startpage125en_US
dc.identifier.endpage132en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster