dc.contributor.authorKahraman, Buse Özcan
dc.contributor.authorÖzsoy, İsmail
dc.contributor.authorAkdeniz, Bahri
dc.contributor.authorÖzpelit, Ebru
dc.contributor.authorSevinç, Can
dc.contributor.authorAcar, Serap
dc.contributor.authorSavcı, Sema
dc.date.accessioned2022-10-12T08:21:13Z
dc.date.available2022-10-12T08:21:13Z
dc.date.issued2020en_US
dc.identifier.citationKahraman, B. O., Ozsoy, I., Akdeniz, B., Ozpelit, E., Sevinc, C., Acar, S., & Savci, S. (2020). Test-retest reliability and validity of the timed up and go test and 30-second sit to stand test in patients with pulmonary hypertension. International journal of cardiology, 304, 159-163.en_US
dc.identifier.issn0167-5273
dc.identifier.issn1874-1754
dc.identifier.urihttps://doi.org/10.1016/j.ijcard.2020.01.028
dc.identifier.urihttps://hdl.handle.net/20.500.12513/4636
dc.description.abstractBackground: Timed up and go (TUG) and sit to stand (STS) tests that required less space and easier to be performed in respiratory and cardiac diseases for assessing functionality. Aim was to test the reliability of TUG and 30-second STS (30STS) tests and determine the validity of TUG and 30STS tests in patients with Pulmonary Hypertension (PH). Methods: Thirty-eight patients with diagnosed PH were included. We collected TUG, 30STS, quadriceps muscle strength, physical activity level, and 6MWT. Intra-class correlation coefficient (ICC) was used to determine test-retest reliability and correlations with quadriceps muscle strength, physical activity level and 6MWT for validity of the TUG and 30STS tests. Results: The TUG and 30STS tests were associated with age, functional class, muscle strength, physical activity and functional exercise capacity in patients with PAH (p < 0.05). 6MWT was associated with age, functional class, muscle strength, physical activity and functional exercise capacity (p < 0.05). ICC (95%) for TUG test and 30STS were 0.96 (0.93-0.98) and 0.95 (0.90-0.97), respectively. Conclusions: The TUG and 30STS tests were reliable and valid tests for measuring physical performance in PH. This study supports using the TUG and 30STS tests as practical assessment tools in patients with PH. (C) 2020 Elsevier B.V. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherTest-Retest Reliability And Validity Of The Timed Up And Go Test And 30-Second Sit To Stand Test İn Patients With Pulmonary Hypertensionen_US
dc.relation.isversionof10.1016/j.ijcard.2020.01.028en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectExercise toleranceen_US
dc.subjectMuscle strengthen_US
dc.subjectCardiovascular diseasesen_US
dc.titleTest-retest reliability and validity of the timed up and go test and 30-second sit to stand test in patients with pulmonary hypertensionen_US
dc.typearticleen_US
dc.relation.journalInternatıonal Journal Of Cardıologyen_US
dc.contributor.departmentFizik Tedavi ve Rehabilitasyon Yüksekokuluen_US
dc.identifier.volume304en_US
dc.identifier.startpage159en_US
dc.identifier.endpage163en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US