dc.date.issued2024en_US
dc.identifier.citationCakmak, M. F., Horoz, L., Kircil, C., Beltir, G., & Basat, H. C. (2024). Intraoperative assessment of the dorso-ulnar fragment stability with stress fluoroscopy: An observational study. Medicine, 103(24), e38509.en_US
dc.identifier.issn00257974
dc.identifier.urihttps://doi.org/10.1097/MD.0000000000038509
dc.identifier.urihttps://hdl.handle.net/20.500.12513/5503
dc.description.abstractThis study aims to investigate the effectiveness of intraoperative stress radiographs in evaluating the stability and fixation adequacy of the dorso-ulnar fragment (DUF) after volar plate application. Sixty-four patients who underwent open reduction and internal fixation due to comminuted distal radius fracture accompanied by DUF between May 2020 and February 2022 were reviewed retrospectively. Two groups were compared, with and without stress radiographs used in addition to routine fluoroscopic imaging during the surgical treatment of distal radius fractures. DUF sizes and fracture classifications were made according to preoperative computed tomography. Displacement of the DUF, dorsal cortex screw penetration, and the number of screws inserted into the DUF were evaluated on immediate postoperative CT scans and direct radiographs. DUF displacement at the patients’ last follow-up was significantly higher in the control group (1.62 mm) than in the additional stress fluoroscopy applied group (0.53 mm). It was observed that the amount of displacement increased as the dorso-volar size of the DUF decreased. No significant difference was observed in dorsal cortex screw penetrations between the 2 groups. In the additional stress fluoroscopy applied group, stabilization rates with at least 1 screw over volar-locking plate for DUF were significantly higher (P < .001). Compared to the stress fluoroscopy group, the change in ulnar variance (P < .001) and volar tilt (P < .001) was significantly higher in the control group in the last follow-up radiography. No significant difference was observed between the implant removal rates of both groups. Evaluation of the stability of the DUF with stress radiographs after fixation is an effective method to reveal the need for additional fi ti D l t di h ll d i l ti f fi ti t th © 2024 Lippincott Williams and Wilkins. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherLippincott Williams and Wilkinsen_US
dc.relation.isversionof10.1097/MD.0000000000038509en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectdistal radius fractureen_US
dc.subjectdorso-ulnar fragmenten_US
dc.subjectintra-articular fractureen_US
dc.subjectstress fluoroscopyen_US
dc.subjectvolar-locking plateen_US
dc.titleIntraoperative assessment of the dorso-ulnar fragment stability with stress fluoroscopy: An observational studyen_US
dc.typearticleen_US
dc.relation.journalMedicine (United States)en_US
dc.contributor.departmentTıp Fakültesien_US
dc.contributor.authorIDMehmet Fevzi Çakmak / 0000-0001-9338-8232en_US
dc.contributor.authorIDLevent Horoz / 0000-0002-7052-207Xen_US
dc.contributor.authorIDHakkı Çağdaş Basat / 0000-0003-3301-2529en_US
dc.identifier.volume103en_US
dc.identifier.issue24en_US
dc.identifier.startpagee38509en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster