Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorAtalay, Eray
dc.contributor.authorTamcelik, Nevbahar
dc.contributor.authorBilgec, Mustafa D.
dc.date.accessioned2019-11-24T21:01:00Z
dc.date.available2019-11-24T21:01:00Z
dc.date.issued2016
dc.identifier.issn1057-0829
dc.identifier.issn1536-481X
dc.identifier.urihttps://dx.doi.org/10.1097/IJG.0000000000000093
dc.identifier.urihttps://hdl.handle.net/20.500.12513/3478
dc.descriptionWOS: 000374819400025en_US
dc.descriptionPubMed ID: 25068467en_US
dc.description.abstractPurpose: To perform a quadrantwise comparison of the minimum distance between the posterior iris and the anterior lens in eyes with pseudoexfoliation syndrome (PXS) and age-matched controls. Patients and Methods: This study was designed as a prospective cross-sectional study. The study population consisted of 60 patients with PXS and 50 age-matched controls. Anterior segment Scheimpflug images of segments 90 to 270, 135 to 315, 180 to 360, and 225 to 45 degrees were exported as high-quality JPEG images (1920 pixels wide, 1048 pixels high; each pixel having a physical dimension of 8.064 x 8.064 mu m) for further evaluation. The images were analyzed by Image J software. Minimum lens-iris distance (MLID) of the superior, inferior, nasal, and temporal quadrants were analyzed and compared between the groups. Anterior chamber depth, anterior chamber angle, pupillary diameter, average of K1 and K2 (Km), and cataract grading system by Scheimpflug imaging [Oculus Pentacam Nucleus Grading System (PNS)] were also assessed. Results: The MLIDs of all quadrants in eyes with PXS were shorter than controls and these differences were statistically significant (P < 0.05). The shortest distance was recorded in the inferior quadrant followed by the superior, temporal, and nasal quadrants in both groups. Pupillary diameter was the only variable found to be correlated with mean global MLID at a statistically significant level (r = -0.465, P < 0.001; adjusted for age, sex, anterior chamber angle, anterior chamber depth, PNS, and Km). Conclusion: Eyes with PXS manifested with shorter mean MLID than controls.en_US
dc.language.isoengen_US
dc.publisherLIPPINCOTT WILLIAMS & WILKINSen_US
dc.relation.isversionof10.1097/IJG.0000000000000093en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectlens-iris distanceen_US
dc.subjectlens-iris channelen_US
dc.subjectpseudoexfoliationen_US
dc.subjectScheimpflugen_US
dc.subjectPentacamen_US
dc.subjectlens displacementen_US
dc.subjectzonule laxityen_US
dc.titleQuadrantwise Comparison of Lens-Iris Distance in Patients With Pseudoexfoliation Syndrome and Age-matched Controlsen_US
dc.typearticleen_US
dc.relation.journalJOURNAL OF GLAUCOMAen_US
dc.contributor.departmentKırşehir Ahi Evran Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri, Göz Hastalıkları ABDen_US
dc.identifier.volume25en_US
dc.identifier.issue1en_US
dc.identifier.startpage95en_US
dc.identifier.endpage100en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları: