dc.description.abstractThis study was conducted to investigate the effectiveness of the fan-pad cooling system and the temperature and relative humidity changes throughout the horizontal distance in the greenhouse. For this purpose, a total of 6 temperature and relative humidity sensors are installed inside and outside of the greenhouse. In the study, it was determined that the system efficiency was the highest when the external relative humidity is the lowest. When the highest outside temperature measured during the day is considered, the outside temperature at 14:00 was 34.98 degrees C, while the average internal temperature values in the greenhouse cooled by fan-pad reached to 26.37 degrees C. The internal temperature in the greenhouse at that hour was found to be 8.61 degrees C lower than the outside temperature. When the sensor positions are considered, the inside-outside temperature difference measured in front of the pad was 12.27 degrees C and the cooling effect measured in front of the pad at that hour was 84.60%, while these values in front of the fan were measured as 8.10 degrees C - 55.85%, respectively. The average temperature increase from the pad to the fan was 5.90 degrees C and the relative humidity difference was by 16% between the cooling hours of 08:00-19:00. In the statistical analyses performed, it was determined that the temperature-dependent relative humidity difference along the horizontal distance is significantly different from the pad to fan (p<0.01).en_US
dc.language.isoengen_US
dc.publisherPARLAR SCIENTIFIC PUBLICATIONS (P S P)en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGreenhouseen_US
dc.subjectfan-paden_US
dc.subjecttemperatureen_US
dc.subjectrelative humidityen_US
dc.titleInvestigation Of The Effectiveness Of The Fan-Pad Cooling System And The Horizontal Temperature And Relative Humidity Changes In The Greenhouseen_US
dc.typearticleen_US
dc.relation.journalFRESENIUS ENVIRONMENTAL BULLETINen_US
dc.contributor.departmentKırşehir Ahi Evran Üniversitesi, Ziraat Fakültesi, Biyosistem Mühendisliği Bölümüen_US
dc.identifier.volume27en_US
dc.identifier.issue12Ben_US
dc.identifier.startpage9755en_US
dc.identifier.endpage9761en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster