dc.identifier.citationGok, A., Urtekin, L., Gok, K., Ada, H. D., & Nalbant, A. (2023). Computer aided analysis of biomechanical performance of schanz screw with different additive manufacturing materials used in pertrochanteric fixator on an intertrochanteric femoral fracture (corrosion resistance approach). International Journal for Numerical Methods in Biomedical Engineering, 39(12), e3763.en_US
dc.identifier.issn20407939
dc.identifier.urihttps://10.1002/cnm.3763
dc.identifier.urihttps://hdl.handle.net/20.500.12513/7355
dc.description.abstractThis study examines the use of computer-aided analysis to evaluate the biomechanical performance of Schanz screws made from different additive manufacturing materials (Ti6Al4V, 316 L, Inconel 625, and Inconel 718) in a pertrochanteric fixator for the treatment of intertrochanteric femoral fractures. Intertrochanteric fractures (ITFs) are severe traumas often seen in the elderly population and can lead to serious consequences. The primary objective of ITF surgery is to provide stability and allow for early ambulation and rehabilitation. The Pertrochanteric Fixator is a surgical implant used to treat hip fractures near the greater trochanter, and is attached to the femur with screws. The procedure is performed under general anesthesia and typically takes 1–2 h. Possible complications include infection, nerve injury, and hardware failure. The aim of this study is to evaluate the biomechanical performance of Schanz screw using computer-aided analysis, comparing the effects of various additive manufacturing materials including Ti6Al4V, 316 L, Inconel 625 and Inconel 718 in a pertrochanteric fixator for intertrochanteric femoral fractures. Additionally, this study will also consider the corrosion resistance of these materials to ensure long-term durability and effectiveness in a clinical setting. The stress values mentioned for the implant materials are as follows. Ti6Al4V: 153.33 MPa, 316 L: 180.98 MPa, Inconel 625: 158.94 MPa, Inconel 718: 148.91 MPa. Higher stress values indicate a greater load transfer to the bone, which can potentially lead to stress shielding. Stress shielding occurs when an implant bears a significant portion of the load that should be transferred to the bone. This reduced stress at the fracture site can prevent the healing process, as bones require adequate stress levels for optimal remodeling and regeneration. © 2023 John Wiley & Sons Ltd.en_US
dc.language.isoengen_US
dc.publisherJohn Wiley and Sons Incen_US
dc.relation.isversionof10.1002/cnm.3763en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAdditive Manufacturing Materialsen_US
dc.subjectBiomechanical Performanceen_US
dc.subjectComputer-aided Analysisen_US
dc.subjectIntertrochanteric Fractures (ITFs)en_US
dc.subjectPertrochanteric Fixator (PTF)en_US
dc.subjectSchanz Screwen_US
dc.titleComputer Aided Analysis of Biomechanical Performance of Schanz Screw with Different Additive Manufacturing Materials Used in Pertrochanteric Fixator on an İntertrochanteric Femoral Fracture (Corrosion Resistance Approach)en_US
dc.typearticleen_US
dc.relation.journalInternational Journal for Numerical Methods in Biomedical Engineeringen_US
dc.contributor.departmentMühendislik-Mimarlık Fakültesien_US
dc.contributor.authorIDLevent Urtekin / 0000-0003-4348-4749en_US
dc.identifier.volume39en_US
dc.identifier.issue12en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster