Voltammetric Behavior of Telmisartan and Cathodic Adsorptive Stripping Voltammetric Method for Its Assay in Pharmaceutical Dosage Forms and Biological Fluids
Yükleniyor...
Dosyalar
Tarih
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
WILEY-V C H VERLAG GMBH
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
Electrochemical behavior of Telmisartan and optimum conditions for its assay were investigated by using cyclic voltammetry and square-wave voltammetry. All studies were based on the quasi-reversible and adsorption-controlled electrochemical reduction signal of TS at about -1.50 V versus Ag/AgCl at pH 10.0 in Britton-Robinson buffer. The peak current was found to change linearly with concentration from 1.69 nM (0.87 mu g/L) to 27.5 nM (14.15 mu g/L). The limit of detection and the limit of quantification were found to be 1.05 nM (0.54 mu g/L) and 3.49 nM (1.79 mu g/L), respectively. The method was successfully applied to different samples with good recoveries at about 100%.
Açıklama
International Conference on Modern Electroanalytical Methods -- DEC 09-13, 2009 -- Sci Charles Univ Prague, Czech Chem Soc, Inst Phys Chem Acad Sci Czech Rep, Prague, CZECH REPUBLIC
WOS: 000281904400025
WOS: 000281904400025
Anahtar Kelimeler
Telmisartan, Square-wave cathodic adsorptive stripping voltammetry, Pharmaceuticals, Spiked human serum, Hanging mercury drop electrode
Kaynak
ELECTROANALYSIS
WoS Q Değeri
Scopus Q Değeri
Cilt
22
Sayı
17-18